Use the following procedure to set or change the interface control value.
NOTE: Press the Mute button momentarily. Do not press this button while pressing other keys/buttons.
| PHY1=status *=change #=OK |
where status is the value of PHY1STAT, defined as:
Depending on the current value, the next sequential valid PHY1 value is selected and displayed as the status. For example, if the current value is 10Mbps HDX (2), pressing * changes the value to 3 (10Mbps FDX). If the current value is 100Mbps FDX (5), pressing * changes the value to 1 (auto).
If a value different from the current PHY1STAT value is entered, the following text displays left-justified at the top of the display:
| Save new value? *=no #=yes |
| PHY2=status *=change #=OK |
where status is the value of PHY2STAT, defined as:
Depending on the current value, the next sequential valid PHY2 value is selected and displayed as the status. For example, if the current value is 10Mbps HDX (2), pressing * changes the value to 3 (10Mbps FDX). If the current value is 100Mbps FDX (5), pressing * changes the value to 0 (disabled).
The following text displays left-justified at the top of the display:
| Save new value? *=no #=yes |
| New value being saved |
The new values are saved and a restart occurs automatically. The user interface is restored to its previous state.
|
|
|